INNOVE-3000HVAC Parameter Table

INNOVE-3000 HVAC / Vaporized Hydrogen Peroxide Air Conditioning Sterilization System

Sterilization curve

Sterilization principle and characteristics
The Innovate-HVAC series VHP sterilizer adopts flash evaporation technology, which vaporizes 30% -35% hydrogen peroxide and quickly and evenly distributes it in the sterilization space through the air conditioning system, achieving 6LOG space sterilization without dead corners; After sterilization, rapid degradation of hydrogen peroxide is achieved, which is non-toxic and residue free. The system adopts a modular design, with four parallel VHP generation modules to ensure the reliability of the system; The sterilization process adopts saturation and dew point control to ensure the vaporization state of hydrogen peroxide. The overall equipment is made of stainless steel material, with a smooth surface and no dead corners; User friendly interface, allowing users to quickly master operational skills; The project management and execution team of the system, from design, production, installation and debugging, parameter development to verification services, can complete turnkey projects in the fields of pharmaceuticals, biosafety, healthcare, and public safety.
operating interface

HVAC Connection Structure Diagram

Control logic of HVAC sterilization system

Key components and roles of process control

Design considerations
Control of hydrogen peroxide vaporization state throughout the entire sterilization process
The occurrence of hydrogen peroxide: It is necessary to ensure the complete breaking of hydrogen bonds and use flash evaporation method
Hydrogen peroxide transportation: fresh air temperature, humidity, and air volume, pipeline preheating, pipeline airtightness
Process control: saturation, dew point control, and cold point control
Coordination of air conditioning system
Loop or non loop mode
Disinfection mode: dehumidification - turn off chilled water to restore room temperature - reduce frequency (about 10 times)
Sealing performance of air duct - material of air duct sealing ring (chloroprene rubber)
Requirements for VHP conveying pipelines
Pay attention to regional and seasonal changes
Insulation, sealing and corrosion resistance of pipelines