Sterilization principle and characteristics

The Innovate-HVAC series VHP sterilizer adopts flash evaporation technology, which vaporizes 30% -35% hydrogen peroxide and quickly and evenly distributes it in the sterilization space through the air conditioning system, achieving 6LOG space sterilization without dead corners; After sterilization, rapid degradation of hydrogen peroxide is achieved, which is non-toxic and residue free. The system adopts a modular design, with four parallel VHP generation modules to ensure the reliability of the system; The sterilization process adopts saturation and dew point control to ensure the vaporization state of hydrogen peroxide. The overall equipment is made of stainless steel material, with a smooth surface and no dead corners; User friendly interface, allowing users to quickly master operational skills; The project management and execution team of the system, from design, production, installation and debugging, parameter development to verification services, can complete turnkey projects in the fields of pharmaceuticals, biosafety, healthcare, and public safety.


operating interface

b6a5414e8e41bde38219967e66dd51d0.png


HVAC Connection Structure Diagram

5a276ae3d900ddbe3c1714e2ed3fd87c.png


Control logic of HVAC sterilization system


1f1901cb9ad65deadecf0814ca67db6a.png


Key components and roles of process control


228777594b6356fe343f405dedbd19ce.png



Design considerations

Control of hydrogen peroxide vaporization state throughout the entire sterilization process

The occurrence of hydrogen peroxide: It is necessary to ensure the complete breaking of hydrogen bonds and use flash evaporation method

Hydrogen peroxide transportation: fresh air temperature, humidity, and air volume, pipeline preheating, pipeline airtightness

Process control: saturation, dew point control, and cold point control


Coordination of air conditioning system

Loop or non loop mode

Disinfection mode: dehumidification - turn off chilled water to restore room temperature - reduce frequency (about 10 times)

Sealing performance of air duct - material of air duct sealing ring (chloroprene rubber)


Requirements for VHP conveying pipelines

Pay attention to regional and seasonal changes

Insulation, sealing and corrosion resistance of pipelines